The tanker truck - distributor is designed for transportation,
temporary storage and refueling
refined and measured
liquid fuels, i.e.: engine fuels
(gasoline), Diesel oil, aircraft
kerosene. It is mounted on an
off-road type chassis. The vehicle
is designed for circulation in
various types of roads, off-road
surfaces included. It may operate
in the temperature range from
-30oC to +50oC.
The tanker is provided with
a pump-measuring unit for
distributing the liquid fuels
with the capacity up to 1000
dm3/min. The unit enables
self-filling of the tanker and
pumping fuels between two
outside tanks.
Technical Specification
(for the tanker of 10.3m3 capacity)
1. Tank:
- total capacity - 10,3m3,
- shell material - carbon steel,
- No of chambers - 1,
- Manhole diameter - 503mm,
- Filler diameter - 200mm,
2. Fuel distribution set:
Fuel pump - self-priming sliding-vane type
- capacity - 1000dm3/min,
- pump drive - hydraulic,
Refining filter
- capacity - 1000dm3/min,
- refining class - 40µm,
- venting - automatic,
Functions of the fuel distribution set
- feeding of filtered and measured fuel from the own
and trailer tanks through four hoses (two hoses on
winding reels) with automatic filling guns (Qmax 4
x 200l/min);
- feeding of filtered fuel without measuring from the
own or trailer tank or from an outside tank 1000l/
min;
- fuel pumping between outside tanks;
- self-filling of the own tank;
- fuel feeding function stepless control;
- possible filling single canisters.
3. Draining filling system:
Unloading - mechanical, gravitational,
Bottom valve - unloaded DN100,
Outlet pipe o100/o80 connecting the bottom valve with:
a) distribution node,
b) outlet nozzle (side locker + rear of the tank),
Outlet valves - DN80 of ball type(at tank side and rear),
Connections - Kamlok type, DN80, fast-acting,
Bottom valve control - pneumatic,
Draining hoses - rubber, DN80, l=4mb, 2pcs.
The system provided with:
- API 100 connector (rear of the tank)
Additional equipment: a set of adaptors ensuring compatibility
with NATO troops (to be agreed upon)
Protections:
- bottom valve DN100 - in case of damaged outlet
system
- respiration valve
- protects from excessive
- over- and underpressure in
the tank
- anti-explosion safety device
- pneumatic fuel level sensor -
delimits filling level
(protection from overfilling)
- optical-acoustic signaling of
the filling level;
- signaling of door and
platform opening, clinometer
|
|